成果報告書詳細
管理番号20140000000455
タイトル*平成25年度中間年報 「がん超早期診断・治療機器の総合研究開発 超早期高精度診断システムの研究開発:血液中のがん分子・遺伝子診断を実現するための技術・システムの研究開発 血中分子・遺伝子診断自動化システムの研究開発 (血中がん遺伝子診断の検体処理自動化システム)」
公開日2015/3/25
報告書年度2013 - 2013
委託先名コニカミノルタ株式会社
プロジェクト番号P10003
部署名バイオテクノロジー・医療技術部
和文要約
英文要約Title:Development of an evaluation system for blood samples (FY2010-2014)FY2013 Annual Report
An accurate inspection system detecting less than 100 CTCs in 10 ml peripheral blood has been developed. For performance confirmation of this system, we set to design and constructed the upgraded prototype II composed of two processing units. One unit has the function of alignment and immunostaining of cells on a cell chip under an automatically-controlled flow conditions. By changing the pump construction this unit could obtain 4 times high throughput performance than before. Another unit functions as optical instruments for detecting rare cells. To identify CTCs among many WBCs, we added imaging function for acquirement of high resolution images of CTC candidates, to the high speed scanning technology. And then we started the construction of algorithm for distinguish between CTC and not CTC. By use of these technologies we have estimated the performance of our system using spiked tumor cells in whole blood. As a results, the recovery of tumor cells was about 70 percentage without depending on the expression level of EpCAM protein, especially MDA-MB-231 cell line, low expressing EpCAM, recovery was higher than CellSearch system. At the next step, we plan to perform a pilot study using breast cancer patient specimen.